Customization: | Available |
---|---|
MOQ: | 200sq.M |
Main Steel Frame: | H Beam |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Advantages |
|
Faster installation |
Single source responsibility |
Lower cost |
Flexibility in expansion |
Large clear spans |
Quality control |
Low maintenance |
Energy efficient roof and wall systems |
Architectural versatility |
Optimized design of steel reducing weight |
Quick delivery and Quick turn-key construction. |
Water-tight roofs & wall coverings |
Pre-painted and has low maintenance requirement. |
The building can be dismantled and relocated easily. |
Clear spans up to 100m without internal columns |
Flexibility in building dimensions |
Fixed deadlines and costs |
|
Weather-tight roof and wall coverings with accessories for long maintenance free exteriors. |
Opinions |
1)We can supply all kinds of steel structures, steel building, metal building, modular house, steel frame for warehouse, workshop, garage etc, steel beams, other riveting and welding parts. |
2)We can also make and develop new parts according to customers' drawings and detailed dimensions. |
|
2.Specifications |
1)Size: MOQ is 200m2, width X length X eave height, roof slope |
2)Type: Single slope, double slope, muti slope; Single span, double-span, Multi-span, single floor, double floors! |
|
3) Base: Cement and steel foundation bolts |
|
4) Column and beam: Material Q345(S355JR)or Q235(S235JR) steel, all bolts connection! Straight cross-section or Variable cross-section! |
|
5) Bracing: X-type or V-type or other type bracing made from angle, round pipe, etc |
|
6) C or z purlin: Size from C120~C320, Z100~Z200 |
|
7) Roof and wall panel: Single colorfull corrugated steel sheet0.326~0.8mm thick,(1150mm wide), or sandwich panel with EPS, ROCK WOOL, PU etc insulation thickness around 50mm~100mm, |
|
8)Accessories: Semi-transparent skylight belts, Ventilators, down pipe, Glavanized gutter, etc |
|
9)Surface: Two lays of Anti-rust Painting! |
|
10) Packing: Main steel frame without packing load in 40'OT, roof and wall panel load in 40'HQ! |
|
3. Design Parameters |
If you need we design for you, pls supply us the following parameter together with detail size: |
1)Live load on roof(KN/M2) |
|
2)Wind speed(KM/H) |
|
3)Snow load (KG/M2) |
|
4)Earthquake load if have 5) Demands for doors and windows |
|
6)Crane (if have) ,Crane span, crane lift height, max lift capacity, max wheel pressure and min wheel pressure! |
Mark | Welding method | Penetration type |
MC | Shielded metal arch welding | CJP-complete joint penetration |
MP | PJP-partial joint penetration | |
GC | Shielded arch welding Self-shielded arc welding |
CJP-complete joint penetration |
GP | PJP-partial joint penetration | |
SC | Submerged arc welding | CJP-complete joint penetration |
SP | PJP-partial joint penetration | |
SL | Electroslag welding |
Backing material type | Single/double side welding | ||
Mark | Material | Mark | Single/double side welding |
BS | Metal backing | 1 | Single side welding |
BF | Other backing | 2 | Double side welding |
Mark | Size of each part on groove |
t | Thickness of welding plate(mm) |
b | Groove root gap or gap between two members(mm) |
h | Groove depth(mm) |
p | Groove roof face(mm) |
α | Groove angle(º) |