Prefab Mobile Container Home for Temporary Accommodation

Product Details
Customization: Available
Size: According to Customer′s Requirememt
Color Reference: Ral
Manufacturer/Factory, Trading Company, Group Corporation
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000
Export Year
2004-03-01
  • Prefab Mobile Container Home for Temporary Accommodation
  • Prefab Mobile Container Home for Temporary Accommodation
  • Prefab Mobile Container Home for Temporary Accommodation
  • Prefab Mobile Container Home for Temporary Accommodation
  • Prefab Mobile Container Home for Temporary Accommodation
  • Prefab Mobile Container Home for Temporary Accommodation
Find Similar Products

Basic Info.

Model NO.
KXD-SBT013
Member of Engineering Team
20
Quality Control
Daily
Life Cycle
50 Years
Construction Period
60 Days
Customer Service
Aftersale Service
Transport Package
Seaworthy Package for Aircraft Hangar
Specification
SGS / ISO/BV
Trademark
KXD
Origin
China
HS Code
9406000090
Production Capacity
2000ton/Month

Product Description

2 storey container housing for camp

1.Technical Data-Standard
 
Technical characteristics of containers type elements
(1)ISO standard dimensions of 20 feet STANDARD containers-optionally 10 up to 30 feet
(2)length=6.058 mm (optionally 3.048 - 9.100 mm)
width=2.438 mm (optionally 3.000 mm)
(3)exterior height=2.591 mm (optionally 2.791 mm or 3100 mm)
(4)inner height = 2.300 mm (optionally 2.500 mm or 2800 mm)
 
container construction difference
ZINCED metal profyles 3 mm connected with scres
 
container painting
(1)option: on customer wish in RAL color
(2)option: painted on customer wish in RAL color
 
Prefab Mobile Container Home for Temporary AccommodationPrefab Mobile Container Home for Temporary AccommodationPrefab Mobile Container Home for Temporary Accommodation


 
container floor opening for forklift
(1)without forklift pockets
(2)option: with forklift pockets for containers up to 7.335 mm
(3)holes distance 1.506mm
 
container roof construction
Prefab Mobile Container Home for Temporary Accommodation


 
container exterior wall and side panels
(1)50 mm poliurethane panel, externally micro-corrugated RAL 9002
internally smooth RAL 9010 (white)
(2)option: 60 mm mineral wool, both side plastificated in RAL 9002
(3)option: 60 mm mineral wool, both side plastificated in RAL 9002, internally enriched chipboard 100 WHITE010 (white)
(4)option: 80 mm poliurethane panel, both side plasticated steel plate RAL 9010 (white)
(5)option: 100 mm poliurethane panel, both side plasticated steel plate RAL 9010 (white)
(6)option: 100 mm mineral wool, both side plasticated steel plate RAL 9010 (white)
(7)option: 120 mm mineral wool, both side plasticated steel plate RAL 9010 (white)
 
container exterior and inner walls
PVC with polyurethane filling 40 mm, clear opening 79/202 cm
 
container windows and doors
(1)option: windows without shutters
(2)option: windows with shutters
 
container isolation, coefficient of thermal resistance
floor - U = 0,37 W / m2k
roof - U = 0,39 W /m2k
wall panels - U = 0,41 W /m2k
windows - U = 2,40 W / m2k
 
Individual KXD container modules
They are assembled in KXD factory production from KXD manufactured elements. They come to the market as finished product as residential or office space equipped with or without equipment. Individual container modules are used as a single objects as bungalows, dormitories, offices, warehouses, shops, workshops and a built MODULE for the construction of various shapes and purposes.
 
dimensions and weights

 
container location preparation

 
container handling and lifting


Packaging & Delivery

Packaging Details:
flat packing in container house
Delivery Detail: 15 days

Specifications
high quality and large span modern quality prefab steel workshop
1.insulated sandwich panel,
2.fast installation
Product Description
high quality and large span modern quality prefab steel workshop  
 
Brief Introduction
Light steel structure building is a new type of building structure system,which is formed by the main steel framework linking up H section,Z section,C section or U section steel components,roof and walls using a variety of panels and other components such windows,doors,cranes,etc.Light steel structure building is widely used as warehouses,workshops,large factories...etc.
Characteristics 
1.Wide span: single span or multiple spans, the max span is 36m without middle column.
2.Low cost: unit price range from USD 30/m2 to USD 60/m2 according to customers request.
3.Fast construction and easy installation.
4. Long using lifespan: up to 50 years.
5.Others: environmental protection, stable structure, earthquake resistance, water proofing, and energy conserving.
 
Specification
 

Material
specification
Length As customer's requirement
Width As customer's requirement
Height As customer's requirement
Column H shaped,Q235/Q345
Beam H shaped,Q235/Q345
Purline C/Z shaped,Q235/Q345
Brace Round bar,Q235
Knee brace Steel angle,Q235
Tie bar Steel round tube,Q235
Roof panel
single steel sheet /sandwich panel

Wall panel 

single steel sheet /sandwich panel  

Door

sandwich panel door/sliding door/rolling door  

Window

PVC window/Aluminium frame,4/5mm thickness glass

Gutter

0.8mm steel sheet/1.2mm steel sheet/3mm steel sheet

Rain Pipe

DN110mm PVC rain pipe

 
 Prefab Mobile Container Home for Temporary AccommodationPrefab Mobile Container Home for Temporary Accommodation
 
Our Services
1. Professional design and engineering team: Full solution for steel structure design.
2. Procurement and Manufacture for all material for prefabricated building. We have a professional procurement team to make sure all the materials are with good quality. And our factory operation under ISO/CE/SGS standard, to make sure the fabrication works with high technology.
3. Site management & Installation supervision, We could send our engineers to help for the installation supervision, you just need to prepare a team which know normal construction works will be O.K. 
 
Process, fabrication and quality control standard on welding groove/beveling of steel structure
1. Purpose
To ensure the welding quality, meeting up the technical requirements of welded members and improve the standardization of our fabrication, we specially formulate this regulation.
2. Application scope
This manual apply for the design, fabricate and inspection of groove joint in terms of manual arc welding, CO2 arch welding, mixed gas arch welding, submerged arc welding and electroslag welding.
3. Design of welding groove
3.1 Key points on design welding groove:
In order to obtain quality groove, it is necessary to choose appropriate form of groove. The option of groove mainly depends on the thickness of base metal, welding method and craftsmanship requirements.The followings are the factors we need to consider:
  1. minimize the amount of filler metal
  2. easy for beveling
  3. in convenience for welding operation and slag removal
  4. After welding stress and deformation should be as small as possible

3.2 Groove direction:
We will consider the following factors for the groove direction:
A)in favor of welding process and removing slag and leave enough space for welding process on the fusion face
B)minimize the times of flip-flop during welding
C)way of fit-up in actual welding

3.3. Regulation on groove direction of members:

3.3.1 Butt welding on H section rafter/column (when CJP-complete joint penetration and single side fusion is required)
1) When there is no welding backing, the groove orientation on flange plates should be same and falls on the direction in favor of welding on web plats(same rules apply for the PJP situation). Please refer to illustration 1
Prefab Mobile Container Home for Temporary Accommodation
2)When there is welding backing, we require the groove direction being outward for the flange plates(opposite direction for web plates) and still falls on the direction in favor of welding on web plates. Please refer to illustration 2
Prefab Mobile Container Home for Temporary Accommodation3)Butt-welding on construction site:we require all the grooves should be bevelled on the upper rafter/column when it comes to bolt connection for web plates(see illustration 3). For the scenario of welding on web plates, please refer to the illustration 4.
Prefab Mobile Container Home for Temporary AccommodationPrefab Mobile Container Home for Temporary Accommodation3.3.2 Box column(groove on itself).See illustration 5

Prefab Mobile Container Home for Temporary Accommodation4. Welding groove form
4.1. Mark on form and size of welding joint groove:
Prefab Mobile Container Home for Temporary AccommodationExample: Shielded metal arch welding, complete joint penetration, butt welding, I shape groove, welding backing and single side weld would be marked MC-BI-BS1
4.2. For the mark of welding method and penetration type, please see the following chart 1.
Chart 1 Mark on welding method and penetration type
Mark Welding method Penetration type
MC Shielded metal arch welding CJP-complete joint penetration
MP PJP-partial joint penetration
GC Shielded arch welding
Self-shielded arc welding
CJP-complete joint penetration
GP PJP-partial joint penetration
SC Submerged arc welding CJP-complete joint penetration
SP PJP-partial joint penetration
SL Electroslag welding  
 4.3. For the mark of single, double side welding and backing material type, please see the following chart 2
Chart 2 Single/double side welding and backing material type mark
Backing material type Single/double side welding
Mark Material Mark Single/double side welding
BS Metal backing 1 Single side welding
BF Other backing 2 Double side welding
4.4. Mark on each part size of groove, see chart 3.
Chart 3 Size mark on groove
Mark Size of each part on groove
t Thickness of welding plate(mm)
b Groove root gap or gap between two members(mm)
h Groove depth(mm)
p Groove roof face(mm)
α Groove angle(º)

Applicable Codes

LATEST INTERNATIONAL CODES COMPLIANCE
A. (GB50009-2012): Load code for the design of building structures
Loads on all buildings are applied in accordance with:
2012 edition of the Load code for the design of building structures

B. (MOHURD): Ministry of Housing and Urban-Rural Development of the People's Republic of  China

Manufacturing and Erection tolerances are applied as per:
GB50205-2001 edition Code for acceptance of construction quality of steel structures


C.(MOHURD): Ministry of Housing and Urban-Rural Development of the People's Republic of  ChinaHot rolled sections and built up sections are designed in accordance with:
GB50017-2017 Code for design of steel structure

D. CISA - China Iron & Steel Association - Latest Edition
Cold formed members are designed in accordance with:
GB50018-2002 Technical code of cold-formed thin wall steel structures


E. (MOHURD): Ministry of Housing and Urban-Rural Development of the People's Republic of  China

Welding is applied in accordance with:
JGJ81-2002 Technical specification for Welding of steel structure of building

F. Surface treatments are applied in accordance with:
GB/T 8923.1 Preparation of steel substrates before application of paints and related products-Visual assessment of surface cleanliness-Part 1: Rust grades and preparation grade of uncoated steel substrates and of steel substrates after overall removal of previous coatings

STRICT DEFLECTION CRITERIA

 
Deflection Type of structural members Deflection Limitation
Vertical Deflection Portal frame rafter Only support corrugated steel sheets roof and cold-formed section purlins L/180
If there is ceiling system L/240
If there is top running crane L/400
Mezzanine floor Main beam L/400
Secondary beam L/250
Purlins Only support corrugated steel sheets roof L/150
If there is ceiling system L/240
Corrugated roof steel sheet L/150
Lateral Deflection Wall panel L/100
Wind columns or wind truss structures L/250
Wall beam Only support corrugated steel sheet wall L/100
Support masonry wall L/180 and 50mm
  Material Specifications

The material standards for which the building components have been designed as per specifications.

STANDARD MATERIAL SPECIFICATIONS
Material Specifications
No Components Specifications Minimum yield strength Applicable Design Code
1 Built -up
(Plates)
GB/T1591-2008 Fy = 34.5 kN/cm2 CISA - China Iron & Steel Association - Latest Edition
2 Hot Rolled
Angles
GB/T3274-2007 Fy = 23.5 kN/cm2 CISA - China Iron & Steel Association - Latest Edition

Beams
GB/T11263-2010 Fy = 23.5 kN/cm2 CISA - China Iron & Steel Association - Latest Edition
3 Cold Form
 

Galvanized
GB/T 2518-2008 Fy = 45.0 kN/cm2 CISA - China Iron & Steel Association - Latest Edition
4 Roof panel/Wall panel
(Zinc)
GB/T12754-2006 Fy = 34.5 kN/cm2 CISA - China Iron & Steel Association - Latest Edition
5 Roof panel/Wall panel
(Alu)
GB/T12754-2006 Fy = 34.5 kN/cm2 CISA - China Iron & Steel Association - Latest Edition
6 X-Bracing Galvanized cable bracing GB/T 700-2006 Fu = 157 kN/cm2 CISA - China Iron & Steel Association - Latest Edition
7 Anchor bolts
 
GB/T 700-2006 Fu = 40.0 kN/cm2 CISA - China Iron & Steel Association - Latest Edition
8 High strength Bolts GB/T 1228-2006 Ft = 30.3 kN/cm2
Fu = 72 to 83 kN/cm2
CISA - China Iron & Steel Association - Latest Edition
9 Machine Bolts
 
GB/T 1228-2006 Ft = 13.8 kN/cm2
Fu = 41.0 kN/cm2
CISA - China Iron & Steel Association - Latest Edition


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier