Technical Specification |
classify |
Name |
Specification & Parameter |
Type |
Standardization |
custom made products, design and manufacture according to client' s demand |
Disassembly and assembly |
not suitable for assemble and disassemble, lower repeating utilization factor. |
Specification |
Length |
No limited, increase expansion joint when length more than 200m. |
Width |
≤ 11m |
Height: |
≤ 3.0m |
Roof slope: |
double slope, 1: 6-1: 4 |
Floors: |
1floor |
Standard |
Ground channel |
Galvanized steel panel pressure, steel panel thickness is 0.8mm |
Post |
Outdoor post is square steel pipe, material is Q235, components make bottom and surface painted process. |
Roof beam |
Triangle roof frame is welded by square steel pipe, components surface is made rust-proof process. |
Purlin |
Purlin is square steel pipe, material is Q235, components surface is made rust-proof process. |
Wall board |
75mm~150mm thickness color steel sandwich panel, white color |
Roof board
(Ceiling board) |
75~150mm thickness color steel sandwich panel, white color |
Roof tiles |
V35-125-350 color steel tiles, blue or red color |
Door |
sandwich panel door, size: 750mm*2000mm; |
Window |
PVC sliding window, conch model |
Options |
Ceiling |
roof board is also ceiling board, so this house don' t need to make ceiling again. |
Canopy |
color steel sheet or color steel sandwich panel canopy |
Door |
compound wooden door, security door, aluminium alloy door |
Electrical accessories |
Supply plan, design and construction according to relevant national norms(220V, 50Hz, with lamp, switches and multi-function sockets. ) |
Water plumbing accessories |
Supply plan, design and construction according to relevant national norms |
Sanitary ware |
Supply according to customer needs |
Furniture and electrical appliance |
Design according to client' s needs |
Desigh
Parameter |
Roof dead load |
0.3KN/m2 |
Roof live load |
0.5KN/m2 |
Wind load |
9 degree, wind load: 0.35KN/m2, design speed: 24m/S(Chinese standard) |
Earthquake resistant intensity |
6 degree |
used temperature |
Scope: -25° C~+50° C |
Installation |
Tools |
electric drill, pulling rivet, electric hammer, spanner, screwdriver etc, need power to install the house |
Efficiancy |
Four skilled labor one day can erect 40m2' s house body |
Transport |
Container |
each 40ft container could load 130~150m2house body material |