CONTAINER TECHNICAL SPECIFICATIONS |
PRODUCT DIMENSION |
6055 x 2435 x 2896mm Mention dimensions of the containers in the contract, All dimensions may vary aprox. ± 50mm |
METAL PARTS |
Q235 , finished power coating |
CEMENT BOARD |
18mm thickness |
TECHNICAL DATA |
EARTHQUAKE CONDITIONS |
1st Degree |
CLIMATE CONDITIONS |
3rd Climate Zone |
SNOW LOAD |
80 Kg/m² |
WIND SPEED |
80 Km/h The product must be fixed to the ground. |
POLYSTYRENE FOAM (EPS) |
EN 13163 |
TRANSMISSION COEFFICIENT OF EXTERNAL WALL |
0,46 W/m²K |
ROOF TRASMISSION COEFFICIENT |
0,26 W/m²K |
FLOOR HEAT TRANSFER COEFFICIENT |
1,24 W/m²K |
CHASSIS LOADING CAPACITY |
200 Kg/m² |
FLOOR |
SYSTEM |
Specially Shaped steel profile and bolted joint construction in use. The floor must be placed on a flat and stable surface. |
FLOOR COATING |
2.5 mm thick PVC vinyl are used on 18 mm thick cement board. |
WALLS |
SYSTEM |
Specially shaped sandwich panel with ROCKWOOL insulation, EPS and Glass wool are as options. |
OUTER SURFACE COVERING |
Ral 9002 electrostatic painted steel sheet. |
INNER SURFACE COVERING |
Ral 9002 electrostatic painted steel sheet. |
WALL INSULATION |
Produced with 50 mm thick 80 kg/m³ rockwool B1 fire class fire resistant, full thermal insulation, healthy and safety materials. |
ROOF |
ROOF SYSTEM |
Special shaped clamped (grooved seam) corrugated metal panels. Rain water will be drained through special clamping system. |
ROOF INSULATION |
Produced with 120 mm thick 14 kg/m³ glass wool B2 fire class fire resistant, full thermal insulation, healthy and safe materials. |
OUTER SURFACE COATING |
Ral 9002 electrostatic painted steel sheet. |
INNER SURFACE COVERING |
Ral 9002 electrostatic painted steel sheet. |
DOORS |
EXTERNAL DOOR |
Made of Metal door frame and 40 mm sandwich panel that is additionaly reinforced with metal and leakproof gasket and PVC joints. |
INTERNAL DOOR |
MDF door with electrostatic painted galvanized metal frame (1980X755mm) |
WINDOWS |
WINDOW |
875x1135 mm PVC window. Windows are single wing and opens 90 degree. |
SILL |
PVC is used on the window sill of the inside edge. |
GLASS |
Double glazing glass. |
PAINTING |
EXTERIOR AND INTERIOR |
Ral 9002 electrostatic painted steel sheet. |
METAL PARTS |
Ral 1019 electrostatic painted steel sheet. |
ELECTRIC INSTALLATIONS |
SYSTEM |
On the plaster |
CABLE |
For plugs 3x2,5 and for lighting 2x1,5 mm2 |
LIGHTING |
LED or optional |
PLUGS AND SWITCHES |
Located in every room. |
SANITARY INSTALLATIONS |
SYSTEM |
On the plaster |
CLOSET PAN |
Ceramic in used. |
CLOSET |
Ceramic in used. |
SHOWER TRAY |
Acrylic . (Shower Trays are not in use in our WC-Shower Container products.) |
SINK |
Ceramic |
FRESH WATER PIPING |
PPRC featured material in use |
WASTE WATER PIPING |
PVC featured materials in use |
ACCESORIES |
Mirror, toilet paper holder and soap holders etc |
WC-SHOWER |
VENTILATION |
Shower curtains are used for shower units. 210mm x 250mm vent is used for shower and WC units. |
FLOOR AND WALL COVERINGS |
The shower floor is covered completly with PVC vinyl. Walls are covered with PVC vinyl up to 1300mm height ( except partition walls). In Wc units, walls and floor are covered with PVC vinyl up to minimum 300 mm. |
DOOR |
For Wc 900mm doors are used, which open outwards. |
LIGHTING |
A Moisture-proof luminaire 2x18 sized fixture is used. |
DELIVERY |
Lifting is made with specially designed brackets and columns. |